Latest News
It’s all smiles at McCain plant thanks to Deritend H&K - 04 December 2009
A brand new washing and de-stoning plant has been installed at McCain’s potato specialities production plant at Wombourne, in the West Midlands. The plant’s entire peeling and processing line has also been updated, and reinstalled in a more flexible and efficient layout - all with expert help from Deritend H&K. read more ...

Flagship West Midlands engineering centre increases capacity - 07 October 2009
Leading industrial maintenance, service and repair group, Deritend Industries, is increasing the levels of skilled staff and engineering repair work carried out at Deritend RMB, the company’s state-of-the-art engineering works in West Bromwich.  read more ...

Deritend Moves Gearbox Production - 20 May 2009
Deritend is intending to move all its West Midlands based gearbox production, repair and fabrication work to its new state-of-the art engineering workshop based at Brandon Way. read more ...

Deritend Takes Action To Protect UK Jobs… - 10 March 2009

UK national industrial maintenance and support group Deritend Industries is taking positive action to protect skilled jobs in the face of a possible continued downturn. read more ...


Deritend goes large… - 25 November 2008
Deritend has significantly increased it’s capacity to build, fabricate and repair large machines with the opening of its new Brandon Way facility read more ...

DERITEND RMB’S GEARBOX EXPERTISE - 19 November 2008
A UK aggregate producer has recently installed a new in-feed conveyor to deliver stone to a large conveyor at a roadstone quarry in the Pennines. read more ...

EUREKA! - 17 October 2008
Severn Trent Water plans to pump 8,000 litres a second with new Archimedes pump system supplied by Deritend  read more ...

NEW GENERAL SALES MANAGER FOR DERITEND & DERITEND RMB - 10 October 2008
Deritend Industries has announced a key appointment; Stuart Hutchinson has accepted the position of General Sales Manager of the Deritend / Deritend RMB & Deritend H&K business units... read more ...

DERITEND POWERS AHEAD WITH ACQUISITION OF H&K - 30 September 2008
Deritend Industries, the national industrial maintenance group, has acquired H&K Industrial Services (H&K) strengthening the company’s position... read more ...

SHEFFIELD BASED PRE-FORMED WINDINGS EXPANDS PRODUCTION FACILITIES BY 30% - 11 September 2008
Pre-Formed Windings of Sheffield, which has recently completed a 30% expansion of the production facilities at its Hackenthorpe site, creating new job oppurtunities... read more ...

DERITEND ACQUIRES GEARBOX SPECIALIST RMB ENGINEERING - 18 September 2007
Since an MBO in March 2001 the intention of The Deritend Group board has been to grow the business  read more ...

UNIQUE ASSET MANAGEMENT SYSTEM IMPROVES PROFITABILITY - 22 August 2007
Deritend has developed
a unique online Portal & Asset database to enable companies with large quantities
of rotating machines
 read more ...

DERIT32
Download Press Release
Download Hi-res Image

REPLACING STANDARD MOTORS WITH HIGH EFFICIENCY TYPES IS FINE, BUT HOW CAN I SAVE ENERGY WITH MY EXISTING INSTALLED MOTOR BASE?…..
Dave Hawley of the Deritend Group gives some advice for energy saving with standard motors

The high cost of energy to industry is ensuring that companies are taking energy saving far more seriously. Everywhere there are examples of companies replacing standard electric motors with high efficiency types. However, even if this replacement movement really became a boom, the vast majority of electric motors in industry would be standard types for years to come. Against this backdrop, a relevant question to ask is “what can be done to save energy on the existing motor stock.” The obvious answer, of course, is to use AC drives more widely. However, this answer is flawed, as by far the largest numbers of AC induction motors presently used by UK industry are operated at fixed speeds. Moreover, because they are operated at fixed speeds, the potential for saving energy with these units has been largely ignored.

With energy consumption in industry having grown by a factor of 3 compared to domestic consumption, since the 1970’s, ignoring the role of energy saving on standard motors is no longer an option. It has been calculated that the annual cost of energy to run an electric motor can amount to ten times its purchase cost. To illustrate this point, typical running costs of fully loaded motors are in the range £1,100 year for a 2.2 kW motor to £18,000 year for a 37 kW one.

The scale of these figures gives some idea of the scope for possible savings by companies with multiple motor installations. However, there is no magic formula to achieve this, just a few simple questions, rules and procedures, which, if asked regularly, and strictly adhered to, can make a substantial difference to the amount of energy being consumed by a company’s motor stock.

The simplest rule of all is to switch motors off when they are not in use. Although this may seem to be an obvious point, good housekeeping routines to ensure motors are turned off when not required can result in significant savings.       

In the past, there have been reservations about switching- off, because of the stresses and strains that this puts on power transmission systems at start-up. Today these reservations are no longer as relevant as they were, due to the wide availability of soft starters.
                                                                                                               
The more gentle start provided by soft starters allows a much higher frequency of starting, which means that idling machinery can be switched on and off more frequently. To facilitate this operation, simple automatic controllers are available which, when combined with a soft starter can convert conveyors, for example, to a quiescent mode whenever material is not being processed.

Dependent upon the operational conditions, hours run etc., very acceptable payback periods can be assured from controlling fixed-speed motor applications in this way. With the relatively high no-load power requirements of much of the industry’s machinery, 20 - 40 kWh, or more, can easily be saved each hour by the simple act of switching off when no material is being processed


Having identified the opportunities for switching-off motor stock, the next stage of an energy conservation programme is to look at how motor efficiency can be improved. The output of a motor, as detailed on its rating plate, is mechanical power stated in kW. Some of the electrical input to a motor disappears as ‘losses’. Motor efficiency indicates the output power obtained for a given electrical input power e.g. a 3 kW motor with 82% efficiency will have an electrical input of 3.66 kW  (3 ÷ 0.82). Clearly, then, the higher the motor efficiency, the less input kW required, and the lower the running costs.

Measures that can be taken to ensure maximum motor efficiency include maintaining good power quality. Motors are designed to operate with a frequency of 50Hz and a sinusoidal waveform; using power with distorted waveforms will only degrade motor efficiency.                                                                                         


Efficiency is also lost when motors are run either above or below their design voltages. The result of over-voltage is a lower power factor, which reduces overall motor effectiveness. The same is true of motors that are operated at less than 95% of their design voltage. They typically lose 2 to 4 points of efficiency, and also suffer service temperature increases of up to 70C, greatly reducing motor insulation life and impairing reliability. In addition, heat also affects motor efficiency, so motors should be shaded from the sun; they should be located in well- ventilated areas, and since dirt acts as an insulator, they should also be kept clean.

Having considered supply considerations and cooling the next relevant question to ask is: “can the speed of my motors be reduced”. It is important to investigate all opportunities for reducing operating speeds, as this has a big impact on running costs. Fans are very often running below their rated output and this is one of the most obvious places for making immediate savings. With fans and pumps, if the speed reduces by half, the power reduces by 87.5%. Variable speed drives are the tool to achieve this power saving; they allow speed to be matched to the demands of the process, delivering enhanced energy efficiency. In contrast, where a fixed single speed is required, this can be achieved either by changing the shaft pulley ratio on a belt drive, or by changing the ratio on a gearbox.

Complementing a speed reduction strategy, motor engineers should seek to optimise transmission efficiency by ensuring that bearings shafts, belts, chains and gears are properly installed and maintained, and are not subject to wear, noise and vibration, all of which can result in running losses. In addition, the installation of the motor itself must be checked to ensure that there is no misalignment. This can cause additional unnecessary loading on motors and, hence, increased energy consumption, plus reduced plant life through additional mechanical loading.
 
With all the key areas covered for improvement in motor efficiency, the next step is to instigate a series of periodic checks on the motor stock as part of a preventative maintenance programme.                                                                      

Inspections should include all mechanical components, and daily or weekly noise, vibration and temperature checks. These should be complemented, approximately twice a year, by testing of the motor winding and the winding to earth resistance, in order to identify insulation problems.

Finally, the preventative maintenance programme should itself be part of a larger, more comprehensive Motor Management Policy (MMP). An MMP is a coherent structured approach to the purchase and repair of a company's motors to enable companies to keep strictly to an energy efficiency policy. It is designed so that the best economic decision is made each time a new piece of plant containing a motor is purchased, or a when a repair or replacement, is necessary.

Some typical recommendation from an MMP include: specifying 'EFF1' or 'EFF2' motors for all new plant with long running periods; always use a qualified and accredited rewind shop; if a rewind cost exceeds 50% to 60% of a new energy efficient motor, but the new motor; always replace very badly damaged motors; if a motor should be replaced but is needed urgently, then repair, providing that action is justified, and the reason for the repair is recorded; repair high efficiency motors in accordance with AEMT/EEBPP guide “The repair of induction motors.

The Deritend Group Ltd
The Deritend Group Ltd provides UK industry with the widest range of maintenance and management services designed to optimise business activities, improve efficiency and reduce costs. The Group operates in eight areas of competence: customised asset management, electro-mechanical, maintenance, energy management, product sales, pre-formed windings, induction services and automation & control. These services are brought to customers through a network of national service centres. Staffed by trained professionals, the centres are on hand 24- hours-a-day, 7- days a week to respond to customer needs and provide effective maintenance solutions.                                                                        
                                                                                                                  
…………. Ends……………
For further information contact: Helen Holman, Marketing Manager, The Deritend Group Ltd, Cyprus Street Off Upper Villiers Street, Wolverhampton, West Midlands WV2 4PB Tel: 01902 – 392315  E-mail:
hholman@deritend.co.uk  WEB: www.deritend.co.uk
Issued by, and electronic versions available from:
Bob Dobson, BDL Matrix Marketing, High Bank, River, Petworth GU28 9AX
Tel 01798 861677 email:
bdl.studio@virgin.net   www.bobdobson.com  


[ Return To List]